Temperature Mapping
Temperature mapping for pharmaceutical storage areas and equipment, from protocol design to the final report.

Which storage locations stay within range?
A wall probe tells you the temperature at one point. It cannot tell you what happens on the top rack, at the door or in the return air path. We place calibrated data loggers throughout the proposed storage area and compare each location with the approved temperature limits.
We plan studies for new installations and for changes to existing storage, such as a revised racking layout or a replacement refrigeration unit. For an occupied room, we agree how to run the study around stock movements and normal operations.
Protocol and logger layout
We agree the storage range, loading conditions and acceptance criteria with your site team. The protocol identifies each logger position on a drawing and explains the choice of locations, study duration and sampling interval.
On-site mapping
We check logger calibration records, place the loggers at the approved positions and record their installation and retrieval times. We document the loading pattern, door openings and other events that may explain the results.
Temperature profiles and excursions
We compare each trace with the acceptance criteria and identify the warmest and coldest storage locations. If a point falls outside the agreed range, we report where it occurred, how long it lasted and what was happening at the time.
Report and monitoring locations
Your team receives the executed protocol, logger layout, calibration records, data files and study report. We identify the storage positions supported by the results, recommend routine probe locations and flag any areas that need investigation or repeat mapping.
Send a floor plan or equipment list, the required temperature range and your target date. If the area is already in use, include the usual loading pattern and any limits on access.